Equilibrium and kinetic profiles

Kinetic diagnostics on VEST — Thomson scattering (TS) and charge exchange spectroscopy (CES) — measure $T_e$, $n_e$, $T_i$ and $V_{tor}$ at discrete $(R, Z)$ points. To become a core_profiles IDS these point measurements must first be mapped onto a flux coordinate using an equilibrium, then fitted to a smooth 1D profile in $\rho$.

vaft.process implements that two-stage pipeline, and vaft.formula.fit_profile provides the underlying 1D fitting engine.

Pipeline

flowchart LR
    A["TS / CES .mat"] -->|machine_mapping| B["ods: thomson_scattering<br/>charge_exchange"]
    E["GEQDSK / equilibrium"] --> C
    B --> C["equilibrium_mapping_*<br/>(R,Z) → ρ"]
    C --> D["profile_fitting_*<br/>ρ → Te, ne, Ti, Vtor"]
    D --> F["core_profiles<br/>profiles_1d"]

The two stages are deliberately separate: mapping depends on the equilibrium, fitting does not. You can re-fit with a different model without recomputing the mapping.

Loading kinetic diagnostics

Raw TS/CES .mat files are turned into IDS nodes by the machine mapping layer:

import vaft
from omas import ODS

ods = ODS()

# thomson_scattering(ods, shotnumber, data_root=None, mat_file=None)
vaft.machine_mapping.thomson_scattering(ods, 46051, vaft.data.data_path("legacy/46051_NeTe.mat"))

# charge_exchange(ods, shotnumber, options="ces", data_root=None, mat_file=None)
vaft.machine_mapping.charge_exchange(ods, 47514, data_root=vaft.data.data_path("legacy/CES_47514.mat"))

data_root accepts either a directory or a path to a specific *.mat file. This populates thomson_scattering.channel[:].position.{r,z}, .t_e.data, .n_e.data (plus _error_upper siblings), and for CES charge_exchange.channel[:].ion[:].{t_i,velocity_tor}.data.

Sample files ship inside the package — see Data structures for the ODS/IDS conventions, and use vaft.data.data_path() to resolve them:

Sample Packaged path
Thomson (shot 46051) legacy/46051_NeTe.mat
Thomson (shot 39915) legacy/NeTe_Shot39915_v9_rev.mat
CES (shot 47514) legacy/CES_47514.mat
GEQDSK (shot 40330) efit/g040330.00320

Stage 1 — equilibrium mapping

Each diagnostic channel sits at a fixed $(R, Z)$. The mapping functions interpolate $\psi(R,Z)$ from the equilibrium and normalize it, returning one $\rho \in [0, 1]$ per channel:

\[\rho = \frac{\psi(R,Z) - \psi_{axis}}{\psi_{boundary} - \psi_{axis}}\]
geq = vaft.data.read_geqdsk(vaft.data.data_path("efit/g040330.00320"))

mapped_rho = vaft.process.equilibrium_mapping_thomson_scattering(ods, geq)
mapped_rho_ces = vaft.process.equilibrium_mapping_charge_exchange(ods, geq)

Both accept a vaft.data.GEQDSK, an OMAS equilibrium ODS, or a legacy flux-surface mapping as geq. Values are clipped to $[0, 1]$, so channels outside the last closed flux surface pile up at $\rho = 1$. Building an equilibrium is covered in Equilibrium.

Stage 2 — profile fitting

n_e_fn, T_e_fn, coeffs_ne, coeffs_te, n_e_rho, T_e_rho = \
    vaft.process.profile_fitting_thomson_scattering(
        ods,
        time_ms=320.0,
        mapped_rho_position=mapped_rho,
        Te_order=3,
        Ne_order=3,
        uncertainty_option=1,       # weight the fit by per-channel error bars
        rho_points=100,
        fitting_function_te="polynomial",
        fitting_function_ne="polynomial",
    )

Note the return order: density first, then temperature. n_e_fn and T_e_fn are callables you can evaluate on any $\rho \in [0,1]$; n_e_rho and T_e_rho are those functions already sampled on a uniform grid of rho_points. coeffs_* is None for the gp and linear methods.

The CES counterpart mirrors it, with ion_index selecting the ion species:

Vtor_fn, Ti_fn, coeffs_vtor, coeffs_ti, Vtor_rho, Ti_rho = \
    vaft.process.profile_fitting_charge_exchange(
        ods,
        time_ms=300.0,
        mapped_rho_position=mapped_rho_ces,
        Ti_order=3,
        Vtor_order=3,
        fitting_function_ti="polynomial",
        fitting_function_vtor="polynomial",
        ion_index=0,
    )

Here too the velocity function comes back before the temperature function.

Fitting methods

fitting_function_* selects the model, and every variant is dispatched to vaft.formula.fit_profile:

Value Model
polynomial $(1-\rho)\cdot P_n(\rho)$ — polynomial with an edge roll-off factor
exponential $(1-\rho)\cdot \exp(P_n(\rho))$ — enforces positivity
sqrt / sqrt_poly fits $P_n$ to $y^2$, returns $\sqrt{P_n}$
sqrt_exp same square-space trick with an exponential basis
core_poly_edge_exp core polynomial blended into an edge exponential via a $\tanh$ transition
gp Gaussian process regression (scikit-learn), with optional anchor points
linear 1D interpolation through the data — no smoothing

The (1-\rho) factor in the polynomial and exponential bases drives the fitted profile toward zero at the boundary, which is usually what you want for $T_e$ and $n_e$ but is a real assumption — gp and core_poly_edge_exp do not impose it.

order only affects the polynomial-family methods; it is ignored by gp and linear.

Calling the fitting engine directly

For data that is not in an IDS, use the engine itself:

y_eval, y_std_eval, fit_function, coeffs = vaft.formula.fit_profile(
    x, y, y_std,
    x_eval,
    order=3,
    uncertainty_option=1,
    fitting_function="gp",
    gp_anchor=(x_anchor, y_anchor, y_std_anchor),   # GP only
    n_restarts_optimizer=5,
)

It returns the profile on x_eval, its standard deviation (zeros for methods that carry no uncertainty estimate), a callable, and the coefficients. vaft.formula.make_fit_function(mode) builds the bare polynomial / exponential basis function if you want to fit it yourself. See Physics formulas for the rest of the formula namespace.

Writing core_profiles

vaft.process.core_profiles evaluates the fit callables and stores the result as a profiles_1d slice:

ods = vaft.process.core_profiles(
    ods,
    time_ms=320.0,
    mapped_rho_position=mapped_rho,
    n_e_function=n_e_fn,
    T_e_function=T_e_fn,
    tol_ms=0.1,
)

It writes, for the new slice index i:

  • core_profiles.profiles_1d[i].timeseconds (time_ms is divided by 1000)
  • core_profiles.profiles_1d[i].grid.rho_tor_norm — 100 uniform points on $[0,1]$
  • .electrons.temperature (eV) and .electrons.density / .density_thermal (m⁻³)
  • .electrons.temperature_fit / .density_fit — the measured channel values on their mapped $\rho$, kept alongside the fit so you can overplot data against model
  • .ion[0] labelled H+, populated with the electron profiles

That last point is an explicit simplification: core_profiles copies $n_e$ and $T_e$ into the ion channel, it does not use CES data. Treat ion[0] as a placeholder unless you overwrite it yourself.

If a slice already exists within tol_ms of time_ms it is replaced rather than duplicated, so re-fitting the same time in a loop is safe.

Synthetic profiles from equilibrium pressure

When there is no Thomson data, profiles can be back-derived from the equilibrium pressure by assuming $n_e$ and $T_e$ share a shape, with $P = 2 n_e T_e e$ and $g(\rho) = \sqrt{P(\rho)/P(0)}$:

# Pin the on-axis temperature (eV) and let density follow
vaft.process.core_profiles_from_eq(ods, Te0_eV=100.0, eq_time_index=0)

# Or pin the density/temperature ratio (m^-3 per eV)
vaft.process.core_profiles_from_eq_ratio(ods, C_ne_over_Te=1.0e17, eq_time_index=0)

Both read equilibrium.time_slice[i].profiles_1d.pressure and write a core_profiles slice at the matching equilibrium time. The factor of 2 absorbs the assumption $T_i = T_e$; there is no $Z_{eff}$ or impurity modelling. These are synthetic profiles — useful to seed a code that needs some kinetic input, not a measurement.

Plotting

vaft.plot has dedicated views for each stage:

vaft.plot.plot_thomson_radial_position(ods, contour_quantity="psi_norm")  # channels on flux surfaces
vaft.plot.plot_thomson_time_series(ods)                                   # raw Te/ne vs time
vaft.plot.plot_thomson_profiles(ods, save_opt=0, file_name=None)          # fitted profiles
vaft.plot.plot_electron_profile_with_thomson(ods)                         # fit vs measurement
vaft.plot.plot_electron_psi_profile(ods)
vaft.plot.plot_electron_time_volume_averaged(ods)
vaft.plot.plot_equilibrium_and_core_profiles_pressure(ods)                # consistency check

plot_equilibrium_and_core_profiles_pressure is the useful sanity check after a fit: if the pressure implied by the kinetic profiles disagrees badly with the equilibrium pressure, the fit or the mapping is wrong.

For CES, vaft.plot.charge_exchange_rho_profiles runs the mapping and fit internally and plots the result in one call:

vaft.plot.charge_exchange_rho_profiles(
    ods, eq=geq, time_ms=300.0, ion_index=0,
    fitting_function_ti="polynomial", Ti_order=3,
)
vaft.plot.charge_exchange_time(ods, ion_index=0)

vaft.plot.plot_TeNe_from_eq(ods, ...) plots the synthetic profiles produced by the core_profiles_from_eq* helpers.

Exporting

To hand fitted electron profiles to an external code:

vaft.process.export_electron_profile_txt(
    n_e_fn, T_e_fn, coeffs_ne, coeffs_te,
    rho_points=100,
    filename="electron_profiles.txt",
)

The file is CSV with the header psi_N, T_e [eV], n_e [m-3].

Full example

import numpy as np
import vaft
from omas import ODS

shot = 40330

geq = vaft.data.read_geqdsk(vaft.data.data_path("efit/g040330.00320"))
ods = geq.to_omas()
vaft.machine_mapping.dataset_description(
    ods, source=shot, options={"source_type": "shot"},
)
vaft.machine_mapping.thomson_scattering(
    ods, 46051, vaft.data.data_path("legacy/46051_NeTe.mat"),
)

mapped_rho = vaft.process.equilibrium_mapping_thomson_scattering(ods, geq)

for t_s in np.asarray(ods["thomson_scattering.time"], dtype=float):
    time_ms = float(t_s) * 1e3
    n_e_fn, T_e_fn, *_ = vaft.process.profile_fitting_thomson_scattering(
        ods, time_ms, mapped_rho,
        Te_order=2, Ne_order=2,
        fitting_function_te="polynomial",
        fitting_function_ne="polynomial",
    )
    ods = vaft.process.core_profiles(ods, time_ms, mapped_rho, n_e_fn, T_e_fn)

vaft.plot.plot_thomson_profiles(ods)

Note that thomson_scattering.time is in seconds while the fitting and core_profiles functions take time_ms in milliseconds — the conversion above is not optional.

Choosing a fitting method

VEST Thomson systems have few channels, so the fit is under-constrained and the method choice matters more than it would on a large device:

  • Start with polynomial at order=2. Higher orders oscillate between sparse channels.
  • Use gp when you want an uncertainty band rather than a point estimate — it is the only method that returns a meaningful y_std_eval.
  • Use core_poly_edge_exp when the edge gradient is the quantity of interest, since the polynomial bases force the profile to zero at $\rho = 1$ regardless of the data.
  • linear is a diagnostic aid, not a physics result: it interpolates the channels exactly and will happily reproduce measurement noise.

Always keep uncertainty_option=1 if error bars exist. With it disabled every channel is weighted equally, including ones the diagnostic itself flagged as unreliable.

References

results matching ""